UL 1569

UL 1569

Single Core PVC Insulated 105°C, 300V Wires

Nysha Part Number Size of Conductor Conductor Construction Insulation Outer Diameter
No.of Strands
Nos
Dia of Strands
(Approx)*
Max Conductor Resistance at
20°C (ohm/km)
Nom Wall
Thickness
Nom Overall
Diameter
Tolerance
AWG Nos mm ABC ATC mm mm mm
NMT-28AWG-BC/TC-(7/0.127)-UL1569-XX 28 7 0.127 223 239 0.38 1.20 ± 0.1
NMT-26AWG-BC/TC-(7/0.16)-UL1569-XX 26 7 0.16 140 150 0.38 1.30 ± 0.1
NMT-24AWG-BC/TC-(7/0.2)-UL1569-XX 24 7 0.20 87.6 94.2 0.38 1.40 ± 0.1
NMT-22AWG-BC/TC-(7/0.254)-UL1569-XX 22 7 0.254 55.4 59.4 0.38 1.55 ± 0.15
NMT-22AWG-BC/TC-(19/0.15)-UL1569-XX 19 0.15
NMT-20AWG-BC/TC-(1/0.813)-UL1569-XX 20 1 0.813 33.9 35.2 0.38 1.60 ± 0.15
NMT-20AWG-BC/TC-(7/0.31)-UL1569-XX 7 0.31 34.6 36.7 0.38 1.75 ± 0.15
NMT-20AWG-BC/TC-(10/0.254)-UL1569-XX 10 0.254
NMT-20AWG-BC/TC-(19/0.19)-UL1569-XX 19 0.19
NMT-20AWG-BC/TC-(20/0.18)-UL1569-XX 20 0.18
NMT-18AWG-BC/TC-(16/0.254)-UL1569-XX 18 16 0.254 21.8 23.2 0.38 2.00 ± 0.15
NMT-16AWG-BC/TC-(26/0.254)-UL1569-XX 16 26 0.254 13.7 14.6 0.38 2.40 ± 0.2
NMT-14AWG-BC/TC-(41/0.254)-UL1569-XX 14 41 0.254 8.62 8.96 0.38 2.75 ± 0.2
NMT-12AWG-BC/TC-(65/0.254)-UL1569-XX 12 65 0.254 5.43 5.64 0.38 3.20 ± 0.2
NMT-10AWG-BC/TC 10 104 0.254 3.409 3.546 0.38 3.85 ± 0.25
80 0.285
NMT-8AWG-BC/TC-(133/0.285)-UL1569-XX 8 133 0.285 2.144 2.230 0.76 5.4 ± 0.4
NMT-7AWG-BC/TC-(210/0.254)-UL1569-XX 7 210 0.254 1.700 1.768 0.76 6.0 ± 0.5
NMT-6AWG-BC/TC-(133/0.36)-UL1569-XX 6 133 0.36 1.348 1.403 0.76 6.8 ± 0.5
NMT-6AWG-BC/TC-(133/0.36)-UL1569-XX 112 0.39
NMT-4AWG-BC/TC-(192/0.38)-UL1569-XX 4 192 0.38 0.848 0.882 0.76 8.6 ± 0.7
NMT-3AWG-BC/TC-(224/0.39)-UL1569-XX 3 224 0.39 0.6727 0.6996 0.76 9.2 ± 0.8
NMT-2AWG-BC/TC-(280/0.39)-UL1569-XX 2 280 0.39 0.534 0.5548 0.76 9.7 ± 0.8

*No. of strands and Dia of strands will be such as to meet the CR Value only

Standard tolerance of ± 5% will be applicable on the number of strands (for strands ≥80)

Printing will only be applicable for 20AWG & bigger sizes

Metre Marking will be provided only ≥ 10AWG

BC/TC is for Conductor Type - Please use only one

BC for Bare Copper, TC for Tinned Copper

XX is for Colour Code as below, XX/XX to be used for bicolours

Code Colour
RD Red
BK Black
YL Yellow
GN Green
BL Blue
WH White
GY Grey
OR Orange
PK Pink
VT Violet
BN Brown

Applications

  • Appliance Wiring Material (AWM)
  • Internal Wiring of Appliances, Panels, Machines, Electrical & Electronic Equipment

Properties

  • Flame Retardant - VW-1, FT-1 & FT-2