UL 1569
Single Core PVC Insulated 105°C, 300V Wires
Core : Single
Conductor : Annealed Bare / Tinned Copper
Standard : UL 1581, UL 758, UL 1569
Temperature Range : 80°C, 90°C, 105°C
Nominal Voltage : 300 V
UL File No. : E536603
Insulation : PVC
Spark test : 3kV AC
Flexibility & Ageing Test : 136°C for 168 hrs
Heat Shock : 136°C for 1 hours
Cold bend test : -10°C for 4 hours
Tensile Strength : min 10.3 N/mm²
Elongation : min 100%
Flammability : VW-1, FT1, FT2
Standard Length : 250/500/1000 mtr ± 10% or 1000/2000/3000 ft ± 10%
Unstandard Length : upto 10% of PO Qty with minimum length of 50mtr
Printing Details : 1569 E536603
AWM xx AWG 105°C 300V VW-1 FT1/FT2 I A/B Nysha Mobility Tech MM/YYYY LLLL Mtrs
| Nysha Part Number | Size of Conductor | Conductor Construction | Insulation | Outer Diameter | ||||
|---|---|---|---|---|---|---|---|---|
| No.of Strands Nos |
Dia of Strands (Approx)* |
Max Conductor Resistance at 20°C (ohm/km) |
Nom Wall
Thickness |
Nom Overall Diameter |
Tolerance | |||
| AWG | Nos | mm | ABC | ATC | mm | mm | mm | |
| NMT-28AWG-BC/TC-(7/0.127)-UL1569-XX | 28 | 7 | 0.127 | 223 | 239 | 0.38 | 1.20 | ± 0.1 |
| NMT-26AWG-BC/TC-(7/0.16)-UL1569-XX | 26 | 7 | 0.16 | 140 | 150 | 0.38 | 1.30 | ± 0.1 |
| NMT-24AWG-BC/TC-(7/0.2)-UL1569-XX | 24 | 7 | 0.20 | 87.6 | 94.2 | 0.38 | 1.40 | ± 0.1 |
| NMT-22AWG-BC/TC-(7/0.254)-UL1569-XX | 22 | 7 | 0.254 | 55.4 | 59.4 | 0.38 | 1.55 | ± 0.15 |
| NMT-22AWG-BC/TC-(19/0.15)-UL1569-XX | 19 | 0.15 | ||||||
| NMT-20AWG-BC/TC-(1/0.813)-UL1569-XX | 20 | 1 | 0.813 | 33.9 | 35.2 | 0.38 | 1.60 | ± 0.15 |
| NMT-20AWG-BC/TC-(7/0.31)-UL1569-XX | 7 | 0.31 | 34.6 | 36.7 | 0.38 | 1.75 | ± 0.15 | |
| NMT-20AWG-BC/TC-(10/0.254)-UL1569-XX | 10 | 0.254 | ||||||
| NMT-20AWG-BC/TC-(19/0.19)-UL1569-XX | 19 | 0.19 | ||||||
| NMT-20AWG-BC/TC-(20/0.18)-UL1569-XX | 20 | 0.18 | ||||||
| NMT-18AWG-BC/TC-(16/0.254)-UL1569-XX | 18 | 16 | 0.254 | 21.8 | 23.2 | 0.38 | 2.00 | ± 0.15 |
| NMT-16AWG-BC/TC-(26/0.254)-UL1569-XX | 16 | 26 | 0.254 | 13.7 | 14.6 | 0.38 | 2.40 | ± 0.2 |
| NMT-14AWG-BC/TC-(41/0.254)-UL1569-XX | 14 | 41 | 0.254 | 8.62 | 8.96 | 0.38 | 2.75 | ± 0.2 |
| NMT-12AWG-BC/TC-(65/0.254)-UL1569-XX | 12 | 65 | 0.254 | 5.43 | 5.64 | 0.38 | 3.20 | ± 0.2 |
| NMT-10AWG-BC/TC | 10 | 104 | 0.254 | 3.409 | 3.546 | 0.38 | 3.85 | ± 0.25 |
| 80 | 0.285 | |||||||
| NMT-8AWG-BC/TC-(133/0.285)-UL1569-XX | 8 | 133 | 0.285 | 2.144 | 2.230 | 0.76 | 5.4 | ± 0.4 |
| NMT-7AWG-BC/TC-(210/0.254)-UL1569-XX | 7 | 210 | 0.254 | 1.700 | 1.768 | 0.76 | 6.0 | ± 0.5 |
| NMT-6AWG-BC/TC-(133/0.36)-UL1569-XX | 6 | 133 | 0.36 | 1.348 | 1.403 | 0.76 | 6.8 | ± 0.5 |
| NMT-6AWG-BC/TC-(133/0.36)-UL1569-XX | 112 | 0.39 | ||||||
| NMT-4AWG-BC/TC-(192/0.38)-UL1569-XX | 4 | 192 | 0.38 | 0.848 | 0.882 | 0.76 | 8.6 | ± 0.7 |
| NMT-3AWG-BC/TC-(224/0.39)-UL1569-XX | 3 | 224 | 0.39 | 0.6727 | 0.6996 | 0.76 | 9.2 | ± 0.8 |
| NMT-2AWG-BC/TC-(280/0.39)-UL1569-XX | 2 | 280 | 0.39 | 0.534 | 0.5548 | 0.76 | 9.7 | ± 0.8 |
*No. of strands and Dia of strands will be such as to meet the CR Value only
Standard tolerance of ± 5% will be applicable on the number of strands (for strands ≥80)
Printing will only be applicable for 20AWG & bigger sizes
Metre Marking will be provided only ≥ 10AWG
BC/TC is for Conductor Type - Please use only one
BC for Bare Copper, TC for Tinned Copper
XX is for Colour Code as below, XX/XX to be used for bicolours
| Code | Colour |
|---|---|
| RD | Red |
| BK | Black |
| YL | Yellow |
| GN | Green |
| BL | Blue |
| WH | White |
| GY | Grey |
| OR | Orange |
| PK | Pink |
| VT | Violet |
| BN | Brown |
Applications
- Appliance Wiring Material (AWM)
- Internal Wiring of Appliances, Panels, Machines, Electrical & Electronic Equipment
Properties
- Flame Retardant - VW-1, FT-1 & FT-2