Co-Axial Cables
Coaxial cables are superior to most other radio/signal transmission lines is that it protects against external interference and electromagnetic fields. An ideal coaxial cable contains its own signal carrying electromagnetic field within the space between the two conductors, thus allowing for installation near metal objects (like ducts and gutters) without the power losses that occur in other kinds of transmission lines.
Furthermore, coaxial cables are used to carry low frequency signals, such as audio signals, where the dimensions of the cable are controlled to give a precise, consistent conductor spacing, which is required for the cable to function efficiently as a radio transmission line or for medical purposes like patient monitoring, ECG etc.
Applications
- Transmission & reception of data processing signals
- RF signal transmission, broadcast, internal wiring of class 2 circuits
- Feed lines connecting radio transmitters & receivers with their antennas
- Computer network connections, cable television networks, Internet & Ethernet
- CCTV & Audio Visual VSAT, medical equipment
- Telecom networks, Antenna System Communication PLCC systems
- Defence – Army, Navy & Aerospace
Features
- High Band Width
- Low Attenuation value
- Minimal structural return loss
- Low losses in signal quality
- Clear reception and reduced cross talk
- Ideal for power pass application
- Armoured, Multicore, Composite, Hybrid, Umbilical Co-axial cables can be provided on request
- Twin Axial, 3 x 3 Twin Axial (RG 108), Tri-Axial, Double Screened Co-Axial, Micro Co-axial cables can be provided on request
Cable Construction
Conductor : Solid / stranded Annealed Bare Copper / Annealed Tinned Copper / Copper Clad Steel / Copper clad Aluminium / Annealed Silver Plated Copper / Silver coated Copper clad Steel
Insulation : Solid Polyethylene / Foam PE / XLPE / FEP / PTFE / ETFE / PVC
Screening : Bare Copper / Tinned Copper / Silver Plated Copper / Aluminium alloy
Outer Sheath : PVC / LSZH / PE / FEP / PTFE / PFA
Electrical Characteristics
| Cable Type | Impedance (Ω) | Resistance (Ω/km) | Capacitance (pf/m) | HV Test (kV) | Attenuation (dB/100m) | ||||
|---|---|---|---|---|---|---|---|---|---|
| 50 MHz | 100 MHz | 400 MHz | 1000 MHz | 3000 MHz | |||||
| RG - 6 | 75 | 360 | 66.6 | 5 | 13.1 | 16 | -- | -- | -- |
| RG - 11 | 75 | 20.3 | 67.3 | 10 | -- | -- | 17.1 | -- | 60.7 |
| RG - 58 | 50 | 4.1 | 105.6 | 5 | 13.1 | 21.3 | 55.8 | 91.9 | -- |
| RG - 59 | 75 | 15.7 | 72.2 | 7 | -- | -- | 29.5 | 52.5 | -- |
| RG - 62 | 93 | 0.5 | 43.3 | 3 | 6.2 | 9.2 | 17 | 27.9 | -- |
| RG - 213 | 50 | 0.6 | 105.6 | 10 | 33.9 | 7.6 | 22.3 | 29.5 | -- |
| RG - 214 | 50 | 28 | 105.6 | 10 | 5.6 | 8.9 | -- | 39.4 | 9.1 |
| RG - 217 | 50 | 3.1 | 96.8 | 12 | -- | -- | 14.1 | -- | 45.9 |
| RG - 174 | 50 | 32 | 105.6 | 2 | 21.3 | 32.8 | 157.5 | 147.6 | -- |
| RG - 178 | 50 | 828 | 95.8 | 1 | -- | -- | -- | 180 | -- |
| RG - 179 | 75 | 802 | 75 | 1.5 | 17 | 24 | 50 | 83 | -- |
| RG - 302 | 75 | 800.5 | 63.7 | 3.5 | 26 | 26.2 | 24.9 | 38.7 | -- |